Description

The MultiChannelTM Array Gauge from SolveTech is used to measure the thickness of plastic film and other non-conductive materials on the production line. It accurately delivers a cast film’s cross web profile, with high precision and in real time. Unlike a typical scanning gauge, the MultiChannelTM has multiple measurement sensing zones that cover the cast film web continuously.

The result is a unique offering to the market that has made it the highest performance unit for webs under 60 inches wide.
Features Content


- Non-scanning, 100% continuous coverage
- Multiple contiguous zones within one unit
- Non-contact
- No moving parts
- C-Frame head styles up to 30″
- Easy to ready display
- Software package for process set-up, monitoring, trouble-shooting/studies, and QC
- Menu-drive setup
- Rear panel analog output
SYSTEM INCLUDES:
- Model CLC Series non-contact, nuclear-free Measurement Head
- Gauge Control Unit
- MC5600-PC Software package
- Associated power cord and cables
The MultichannelTM Array Gauge provides multiple fixed points across the web. The measurement areas are usually contiguous and provide complete coverage with no scanning. The high frequency response allows complete data on your web.

RADIATION-FREE
Our dielectric-based technology means fast, accurate measurements without the environmental or regulatory concerns associated with nuclear gauges.
FAST DATA COLLECTION
The MultichannelTM Array Gauge provides extremely fast response, allowing it to sense even brief, transient web variations. Having an array of channels make true profile and product mapping available for the first time.
ACCURATE AND RELIABLE
Quick response features combined with proprietary Measurement head design allow the MultichannelTM Array Gauge to provide 100% continuous coverage of your cast film web with excellent accuracy. Accuracies typically range between 0.1% and 1%, depending on the application. Precision better than 0.1 microns can be achieved.
Technical Indexes Content
TECHNOLOGY
SolveTech’s proprietary capacitance technology
Non hazardous low voltage electric field
PRECISION
0.01 mil (0.25 Micron)
Typically 1% to 0.1% of material thickness. Higher and lower precision is possible depending on measurement footprint design
MEASUREMENT GAP
Typically 0.1″ to 0.25″
Customizable – Up to 1″ possible
VOLTAGE
110V 60Hz Standard/220V Available
All international frequencies and voltages available
TYPICAL CHANNEL SIZE
1 inch in the cross web, 2 inches in the machine direction
Channel size is customizable
CHANNEL COUNT
2 to 32 Channels
Only gauge on the market that offers multiple independent channels directly adjacent to each other.
DATA COLLECTION
Every Second
TRAVEL DISTANCE OF THE SLIDE
Exceeds the throat depth on the unit
Other lengths available upon request
LINEARITY
+/-0.1%
Reduces the flutter effects in the gauge, and reduces recipe count. Market leading pass line performance
STABILITY
Stable year after year, no re-calibration required
Market Leading